Unit of measurement | Turbo 150 | ||
Connected air duct size | mm | 150 | |
Phases | - | 1 | |
Minimum supply voltage | V | 230 | |
Maximum supply voltage | V | 230 | |
Power supply frequency | Hz | 50/60 | |
Rated power | W | 42 | 50 |
Unit current | A | 0.19 | 0.22 |
Maximum airflow | m3/h | 415 | 565 |
rotation speed at 50hz | - | ||
Sound pressure level LpA at 3 m | dB(A) | 32 | 44 |
Weight | kg | 2.95 | |
Transported air temperature (max) | °С | 60 | |
Ambient air temperature min | °С | 0 | |
Ambient air temperature max | °С | 0 | |
Ingress protection rating | - | IPX4 | |
Ingress protection rating of the drive | - | IPX4 |
Trademark | Blauberg | |||||
Model | Turbo 150 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) | Cold | Average | Warm | |||
53.8 | A+ | 26.7 | B | 11.2 | E | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 500 | |||||
Electric power input (W) | 50 | |||||
Reference flow rate (m3/s) | 0.097 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.12 | |||||
Control typology | Local demand control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Sound power level (dB(A)) | 66 | |||||
Declared typology | RVU UVU | |||||
The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
64 | 64 | 64 | ||||
The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
5536 | 2830 | 1280 |