| Unit of measurement | Vento Expert A50-1 S W V.2 | |||
| Phases | - | 1 | ||
| Minimum supply voltage | V | 100 | ||
| Maximum supply voltage | V | 240 | ||
| Power supply frequency | Hz | 50/60 | ||
| Rated power | W | 4.45 | 5.08 | 7.06 |
| Unit current | A | 0.035 | 0.04 | 0.059 |
| Air flow in ventilation mode | m³/h | 15 | 30 | 50 |
| Air flow in heat recovery mode | m³/h | 8 | 15 | 25 |
| Rotation speed at 50hz | - | 800 | 1300 | 1900 |
| Sound pressure level LpA at 3 m | dB(A) | 11 | 18 | 21 |
| Sound pressure level LpA at 1 m | dB(A) | 20 | 27 | 30 |
| Heat recovery efficiency, max | % | 93 | ||
| Heat exchanger type | - | Reversible | ||
| Heat exchanger material | - | Ceramic | ||
| Filter | - | G3 (Option: F8 PM2,5 > 99 %*) | ||
| Transported air temperature (max) | °С | 40 | ||
| Transported air temperature (min) | °С | -20 | ||
| Ingress protection rating | - | IP24 | ||